how does the incinerator works

how does the incinerator works? the incinerator mainly for medical waste and animal waste treatment with oil/gas fired
in the primary chamber with high temeprature and the secondary chamber fired the gas from the parimary chamber with
higher temeprature average 1000-1200 or more to 1600 degree. afterburnning is smoke scrubber with dry or wet scrubber
system. incinerator is top 1 section for bio medical waste and other like covid19 ppe waste.

 

 
Nanjing Clover Medical Technology Co.,Ltd.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100-150 kg/hour 150-200 kg/hour 300-400 kg/hour 500-600 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

liquid incinarator supplier in uae
incinerator meaning
proper disposal incinerator ash
pyrolytic hot hearth medical waste disposing machine manufacturers in europe
comment fabriquer un incinérateur de déchets

All electrical connections attached with the incinerator and other machinery should be provided with suitable and necessary safety devices and be protected by steel conduits, cable trays, and supports.
The manufacturer should permanently mark on the incinerator indicating: (i) manufacturer’s name or trademark (ii) style, type, model or, date of manufacture of the incinerator (iii) capacity in terms of net designed heat release in heat units per timed period (i.e., British Thermal Units per hour, mega joules per hour, kilocalories per hour).
Operations store “The unit shall be supplied with a lockable operations store, that shall be initially supplied with the following consumables:
• A first aid kit, suitable for addressing the hazards presented by the unit.
• 5 full sets of personal protective clothing and equipment.
• Operating logbooks.
• Unit cleaning equipment.
• Unit routine maintenance equipment and associated spare parts.
• Lubricants as appropriate.
• 3 Fire extinguishers.
• Any other consumables considered necessary by the Supplier.

 
 
 
 
 
 
 

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

 
Mobile: +86-138139 31455(WhatsApp)

Website: www.hiclover.com 
Email:     [email protected]       
Email:    [email protected]