a. be based on common, well-proven and clean technology – both as a complete unit and in terms of its individual components.
b. be very robust, sturdy and capable of installation in remote locations subject to severe conditions.
d. generate residual incinerator ash conforming to <10% by volume and <25% by weight of the waste incinerated.
e. achieve a Total Organic Carbon (TOC) content in the slag and bottom ashes of less than 3%.
g. include clearly readable system operation panels.
h. include an operator’s manual (in English and French and Spanish).
i. require minimal preprocessing i.e. there shall be no/very limited need for prior sorting, crushing or shredding.
j. be capable of handling mixed solid waste streams and incinerable hazardous wastes as indicated.
k. can accommodate large variations in waste composition and calorific value.
l. allow for batch loading
m. incorporate an Air Pollution Control System suitable for basic emission control
n. have a thermal efficiency of not less than 85%.
o. primary and secondary chambers shall preferably have rounded inside corners to avoid the formation of dead zones or cold pockets
p. have very low levels of unburned material in the slag
q. include a supplement fuel source and storage unit (e.g., diesel tank),
“r. proposals shall include the fuel consumption at the rated capacity
be CE Certified, meet relevant British, EU or American Standards, or equivalent.
“
The proposed incinerator units must be complete and include all of the key features listed below and all of the associated support services and interconnections
The forecasted feedstock loads, and daily loading rates are generally summarized as:
• Mixed general, clinical and incinerable hazardous wastes with a wide range of calorific values and densities. The wastes will consist of 100% biomedical wastes.
• Wastes either small enough to fit within a 60 litre waste sack or broken up or shredded to less than 300mm in size.
• Operation on a daytime shift basis, 5 days per week.
• An 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading if required. The automated burn completion and cool down cycle will take place overnight.
• The incinerators shall be capable of using diesel fuel as a supplemental fuel while the associated management equipment shall be capable of using electricity as the primary power source.
• Also consider provision for meeting international emission standards.
Able to handle an average waste production of 100kg/day
“• Minimum load capacity: 20 kg
• Maximum load capacity: 40 kg
• Nominal burning rate: 10-30 kg/hr (= 80- 240 kg range per 8hour day)
Tel: +86-25-8461 0201
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
medical waste incinerators,incinerators china
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | |
Burn Rate (Average) | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | |
Control Mode | PLC Auto. | PLC Auto. | PLC Auto. | PLC Auto. | |
Combustion Chamber | 100L | 210L | 330L | 560L | |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | |
Secondary Chamber | 50L | 110L | 180L | 280L | |
Smoke Filter Chamber | Dry Scrubber | Dry Scrubber | Dry Scrubber | Dry Scrubber | |
Feed Mode | Manual | Manual | Manual | Manual | |
Voltage | 220V | 220V | 220V | 220V | |
Power | 0.75Kw | 0.83Kw | 0.99Kw | 1.2Kw | |
Diesel Oil Consumption (kg/hour) | Ave.8.4 | Ave.10.9 | Ave.13.3 | Ave.16.9 | |
Natural Gas Consumption (m3n/hour) | Ave.10.1 | Ave.13 | Ave.16 | Ave.20.2 | |
Temperature Monitor | Yes | Yes | Yes | Yes | |
Temperature Protection | Yes | Yes | Yes | Yes | |
Items/Model | TS100(PLC) | TS150(PLC) | TS300(PLC) | TS500(PLC) | |
Burn Rate (Average) | 100 kg/hour | 150 kg/hour | 300 kg/hour | 500 kg/hour | |
Control Mode | PLC Auto. | PLC Auto. | PLC Auto. | PLC Auto. | |
Combustion Chamber | 1200L | 1500L | 2000L | 3000L | |
Internal Dimensions | 120x100x100cm | 150x100x100cm | 170x120x100cm | 210x120x120cm | |
Secondary Chamber | 600L | 750L | 1000L | 1500L | |
Smoke Filter Chamber | Dry Scrubber | Dry Scrubber | Dry Scrubber | Dry Scrubber | |
Feed Mode | Manual | Manual | Manual | Manual | |
Voltage | 220V | 220V | 220V | 220V | |
Power | 1.38Kw | 1.69Kw | 2.57Kw | 4.88Kw | |
Diesel Oil Consumption (kg/hour) | Ave.20.4 | Ave.24.2 | Ave.33 | Ave.44 | |
Natural Gas Consumption (m3n/hour) | Ave.24.5 | Ave.29 | Ave.39.6 | Ave.52.8 | |
Temperature Monitor | Yes | Yes | Yes | Yes | |
Temperature Protection | Yes | Yes | Yes | Yes |