Pre-assembled containerized type Incinerator

Pre-assembled, containerized type Incinerator

Model

CA100

Picture

Waste Treatment

Medical Waste Incineration Treatment

Feed Capacity

Average 100-200 kgs per feed

Burning Rate

Average 100-120 kgs per hour

Burning Time per Feed

Average 1-2 hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Voltage

220V

Power

1.0Kw

Fuel

Diesel oil

Burner

Italy Burner

Feed Mode

Manual

Temperature Monitor

Digital Display

Fuel consumption (Oil)

Average 20.4 Kgs/Hour

Internal Dimensions

100x80x70cm (Primary Combustion Chamber)

External Dimensions

230 x 130 x 155cm (main body)

Waste combustion chamber

560Liters

Post Combustion Chamber

280Liters

Oil Tank Capacity

200 Liters

Door Opening

70 x 50cm

Chimney

5.0M

Gross Weight

4500kgs

Chamber Material

Firebrick ,Refractory Concrete

Max. Heat Value

166,000Kcal/Hr.

Operation Technical Specifications

Solid Chamber temperature

8000C -10000C

Gas Chamber temperature

10000C -12000C

Chamber Anti-Rate

17500C

Residency time

2.0 Sec.

Burning efficiency

98%

Waste Lower Calorific Power

3000Kcal

Pre-assembled, containerized type do not included chimney installation,containerized  mobile type.
 Burning rate: 100 – 120kg / hour
 Minimum operating temperature: 800-1000 degree
  (Primary combustion)
Maximum operating temperature: 1000-1200 degree  (afterburner chamber)
Secondary Burning capacity: Compulsory.
Density insulation: 50mm high
Refractory casting: minimum 114mm
Heavy duty refracting lining to withstand 1750 degree
Average burn out time: maximum 1-2 hours
Fuel type: fuel oil (diesel)
Fuel consumption in L/hr: average 20.4 liter/Hr.
Residency time in secondary chamber: 2 secs.
Residue ash post 100kg Max 3.8 kg
Installation period Maximum 7days.
State: Anambra Sites:
General Hospital Onitsha
General Hospital Enugwu Ukwu
General Hospital Ekwulobia
Orumba General Hospital
II. State: Benue Sites:
North East Senatorial zonal waste collection site (zone A): EPI Office Katsina-Ala LGA
North West Senatorial zonal waste collection site (zone B): EPI Office Gboko LGA
Benue South zonal waste collection site (zone C): EPI Office Otukpo LGA
Benue State Capital: Central Medical Store, Makurdi
III. State: Kogi Sites:
University Teaching Hospital, Anyigba, Dekina LGA
General Hospital Obangede, Okehi LGA
General Hospital Mopa-Muro LGA
IV. State: Ebonyi Sites:
General Hospital Ezzango, Ebonyi North Zone
 General Hospital Onueke, Ebonyi Central Zone
External L= 3235, W=1150, 1950/3825,Internal L=1600, W=675, H=700;Chamber volume(m3)=0.76;Weight(appox tonne)=3.6,max load capacity (kg) 300, Nominal burn rate uk(kg/hr.)=<50,Thermal capacity(kw) =390, power supply 50/60Hz =220-250v,Door Apertune = 67×550; Hot earth principle = double pass, Fuel type Diesel; Control Panel = Al, Insulation board 25 mm super wool, insulation fire brick =grade E23, Fire brick(Alumina) =42.5%
incinerator capable of a load of upto 50kg/hr.
Twin chamber and should be diesel fuel fired complete with automatic temperature controller upto 900` Celsius.
incinerator (2 equipment) 500kg/hr for face mask disposables.
Automatic smoke free incinerator of capacity 150-200kg/hr for industry. The waste cab be comprises of following types:-
         i.            Wet waste.
       ii.            Plastic wrappers,
      iii.            Solid waste(wood, papers, cartoon box and others).
V. State: Imo Sites:
 Nwabosi Health Center, Nwabosi settlement Isiekenesi ward 2, Ideato South LGA
 Comprehensive Health center, Umuezeala Owerre ward, Ehime Mbano LGA
 Nnenasa Health Center, Umugba settlement, Umueze ward Njaba LGA
General Hospital Owerri Umuguma settlement, New Owerri ward 1
VI. State: Oyo Sites:
State cold store Jericho, South-West LGA, Ibadan
Oyo East Local Government Secretariat, Oyo East LGA
Adebayo Alata Primary Health Care Center (PHC), Ogbomosho South LGA
Itesiwaju NPI Office, Out Itesiwaju LGA
Saki West NPI Office, Saki West LGA
Ibarapa Central NPI Office, Ibarapa Central LGA
VII. State: Kwara Sites:
Ifelodun LGA
Ilorin West LGA
VIII. State: Enugu Sites:
Nsukka District Hospital, Nsukka Town, Nsukka LGA
Agbani District Hospital, Agbani Town, Nkanu West LGA
Udi District Hospital, Udi Town, Udi LGA
IX. State: Enugu MSites:
Odukpani LGA
Obubra LGA
Boki LGA


HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-30